| dc.contributor.author |
Rajput, P. |
|
| dc.contributor.author |
Sabat, K.C. |
|
| dc.contributor.author |
Paramguru, R.K. |
|
| dc.contributor.author |
Bhoi, B. |
|
| dc.contributor.author |
Mishra, B.K. |
|
| dc.date.accessioned |
2018-10-01T12:25:34Z |
|
| dc.date.available |
2018-10-01T12:25:34Z |
|
| dc.date.issued |
2014 |
|
| dc.identifier.citation |
Ironmaking & Steelmaking, 41(10), 2014: 721-731 |
|
| dc.identifier.issn |
0301-9233 |
|
| dc.identifier.uri |
http://ore.immt.res.in/handle/2018/2009 |
|
| dc.description.abstract |
This paper describes the effects of various parameters on the reduction of hematite in the presence of microwave assisted non-thermal hydrogen plasma. The parameters include microwave power, hydrogen flowrate, pressure, microwave power density and temperature. It has been shown that hydrogen flowrate, pressure and microwave power are interrelated to effect the microwave power density that controls the plasma temperature. The experimental conditions encounter three temperatures: surrounding the sample, associated with the plasma and at the plasma/substrate interface. It has been deduced that the third one is the most effective in determining the rate of the reaction, and in the present case, activation energy of 20 kJ mol(-1) is reported. |
|
| dc.language |
en |
|
| dc.publisher |
Maney Publishing |
|
| dc.relation.isreferencedby |
SCI |
|
| dc.rights |
Copyright [2014]. All efforts have been made to respect the copyright to the best of our knowledge. Inadvertent omissions, if brought to our notice, stand for correction and withdrawal of document from this repository. |
|
| dc.subject |
Materials Sciences |
|
| dc.subject |
Materials Sciences |
|
| dc.title |
Direct reduction of iron in low temperature hydrogen plasma |
|
| dc.type |
Journal Article |
|
| dc.affiliation.author |
CSIR-IMMT, Bhubaneswar 751013, Odisha, India |
|