Online Repository of E-contents (ORE)

A comparative study on extraction of Mo(VI) using both solvent extraction and hollow fiber membrane technique

Show simple item record

dc.contributor.author Rout, P.C.
dc.contributor.author Sarangi, K.
dc.date.accessioned 2018-10-01T12:25:07Z
dc.date.available 2018-10-01T12:25:07Z
dc.date.issued 2013
dc.identifier.citation Hydrometallurgy, 133, 2013: 149-155
dc.identifier.issn 0304-386X
dc.identifier.uri http://ore.immt.res.in/handle/2018/1826
dc.description Ministry of Earth Sciences, Govt. of India
dc.description.abstract A comparative study between solvent extraction and hollow fiber membrane technique has been carried out for the extraction of Mo(VI) from an aqueous sulfate solution. Effect of different parameters such as pH of feed solution, flow rate, extractant concentration, metal ion concentration and strip solution concentration on molybdenum extraction has been investigated. The molybdenum flux, J(Mo) increased with increase of pH and flow rate up to 1.5 and 420 mL/min., respectively and beyond that it decreased. With increasing LIX 841 concentration from 0.08 to 0.8 M, J(Mo) increased from 2.04 to 14.57 x 10(-6) mol/m(2).s, but remained constant beyond that concentration. From the equilibrium study the extracted species was determined to be MoO2R2 center dot RH. Also separation of Mo was carried out from a solution bearing Mo, Cu, Fe, Mn, Zn, Co and Ni and the separation factor values were found in the order of D-Mo/D-Cu<D-Mo/D-Fe<D-Mo/D-Zn<D-Mo/D-Co<D-Mo/D-Mn<D-Mo/D-Ni. The conditions for solvent extraction study of Mo(VI) were optimized and extraction of Mo(VI) was carried out in a mixer-settler with three stage extraction and two stage stripping. The data generated from the hollow fiber study were compared with that of conventional mixer-settler study. (C) 2013 Elsevier B.V. All rights reserved.
dc.language en
dc.publisher Elsevier
dc.relation.isreferencedby SCI
dc.rights Copyright [2013]. All efforts have been made to respect the copyright to the best of our knowledge. Inadvertent omissions, if brought to our notice, stand for correction and withdrawal of document from this repository.
dc.subject Materials Sciences
dc.subject Materials Sciences
dc.title A comparative study on extraction of Mo(VI) using both solvent extraction and hollow fiber membrane technique
dc.type Journal Article
dc.affiliation.author CSIR-IMMT, Bhubaneswar 751013, Odisha, India